A practical reference on Chromatogram: what it is, how it behaves, what the literature reports, and where the honest uncertainties sit.
This page was last updated on 2026-07-23 and is reviewed periodically as new material appears.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
| Property | Value | Notes |
|---|---|---|
| Column particle size | 3–5 µm for conventional HPLC; sub-2 µm for UHPLC | Smaller particles increase backpressure and efficiency. |
| Typical flow rate | 0.5–2.0 mL/min for a 4.6 mm internal diameter column | Flow scales with column diameter and particle size. |
| UV detection wavelength | 190–400 nm | Selection depends on analyte chromophore. |
| Column temperature | 25–40 °C | Temperature affects retention, selectivity, and pressure. |
| Injection volume | 1–20 µL | Larger volumes may distort early-eluting peaks. |
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
Method validation establishes that an HPLC procedure is suitable for its intended use. Key parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Accuracy measures agreement with a true or accepted value, while precision describes repeatability and intermediate precision. Specificity confirms that the method measures the analyte without interference from impurities, degradants, or excipients. Validation is documented in a protocol and report, and acceptance criteria are set before experiments begin. Regulatory guidance varies by region, but the general principles are widely harmonized.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Common checks include retention time, peak area, resolution between critical pairs, tailing factor, and theoretical plate count. Results are compared with predefined limits, and a failed check requires investigation before sample results are reported. Quality control samples at low, middle, and high concentrations are injected at intervals to monitor accuracy and precision. Blank injections detect carryover and contamination, while control charts track performance over time.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
GOT1/cAST, the cytosolic isoenzyme derives mainly from red blood cells and heart. GOT2/mAST, the mitochondrial isoenzyme is present predominantly in liver. These isoenzymes are thought to have evolved from a common ancestral AST via gene duplication, and they share a sequence homology of approximately 45%. AST has also been found in a number of microorganisms, including E. coli, H. mediterranei, and T. thermophilus. In E. coli, the enzyme is encoded by the aspCgene and has also been shown to exhibit the activity of an aromatic-amino-acid transaminase (EC 2.6.1.57).
UniProt is an online repository of protein sequence and annotation data, distributed in UniProt Knowledgebase (UniProt KB), UniProt Reference Clusters (UniRef) and UniProt Archive (UniParc) databases. Originally conceived as the individual ventures of EMBL-EBI, Swiss Institute of Bioinformatics (SIB) (together maintaining Swiss-Prot and TrEMBL) and Protein Information Resource (PIR) (housing Protein Sequence Database), the increase in the global protein data generation led to their collaboration in the creation of UniProt in 2002. The protein entries stored in UniProt are cataloged by a unique UniProt identifier. The annotation data collected for the each entry are organized in logical sections (e.g. protein function, structure, expression, sequence or relevant publications), allowing a coordinated overview about the protein of interest. Links to external databases and original sources of data are also provided. In addition to standard search by the protein name/identifier, UniProt webpage houses tools for BLAST searching, sequence alignment or searching for proteins containing specific peptides.
In 2004, development of an antisense therapy for spinal muscular atrophy began. Over the following years, an antisense oligonucleotide later named nusinersen was developed by Ionis Pharmaceuticals under a licensing agreement with Biogen. In December 2016, nusinersen received regulatory approval from FDA and soon after, from other regulatory agencies worldwide. As of 2020, more than 50 antisense oligonucleotides were in clinical trials, including over 25 in advanced clinical trials (phase II or III). A follow-on drug to Inotersen is being developed by Ionis Pharmaceuticals and under license to Akcea Therapeutics for hereditary transthyretin-mediated amyloidosis. In this formulation the ASO is conjugated to N-Acetylgalactosamine enabling hepatocyte-specific delivery, greatly reducing dose requirements and side effect profile while increasing the level of transthyretin reduction in patients.
Sources: en.wikipedia.org
At the regulatory site, the binding of a ligand may elicit amplified or inhibited protein function. The binding of a ligand to an allosteric site of a multimeric enzyme often induces positive cooperativity, that is the binding of one substrate induces a favorable conformation change and increases the enzyme's likelihood to bind to a second substrate. Regulatory site ligands can involve homotropic and heterotropic ligands, in which single or multiple types of molecule affects enzyme activity respectively. Enzymes that are highly regulated are often essential in metabolic pathways. For example, phosphofructokinase (PFK), which phosphorylates fructose in glycolysis, is largely regulated by ATP. Its regulation in glycolysis is imperative because it is the committing and rate limiting step of the pathway. PFK also controls the amount of glucose designated to form ATP through the catabolic pathway. Therefore, at sufficient levels of ATP, PFK is allosterically inhibited by ATP. This regulation efficiently conserves glucose reserves, which may be needed for other pathways. Citrate, an intermediate of the citric acid cycle, also works as an allosteric regulator of PFK.
ACC Synthase is 450-516 amino acid long sequence depending on the species of plant from which it is extracted. Though it is comparable in the species in which it is found, its COOH-terminal domain is more variable, leading to differences such as oligomerization. The COOH-terminal domain is responsible for oligomerization. In most ACC Synthase producing cells, ACC Synthase exists as a dimer. However, in some we find a monomer ("which is more active and efficient [than its dimer counterpart"). The structure of ACS has been largely determined via X-ray crystallography. Conservation of the residues in ACS's catalytic domain and sequence homology suggest that ACS catalyzes the synthesis of ACC in a similar fashion as other enzymes that require PLP as a cofactor. However, unlike many other PLP-dependent enzymes, Lys (278) is not the only residue that interacts with the substrate. The proximity of the electronegative oxygen from Tyr (152) to the C-γ-S bond suggests a crucial role in the formation of ACC. X-ray crystallography with aminoethoxyvinylglycine (AVG) a competitive inhibitor confirmed Tyrosine's role in the γ elimination. As of late 2007, 6 structures have been solved for this class of enzymes, with PDB accession codes PDB: 1B8G, PDB: 1IAX, PDB: 1IAY, PDB: 1M4N, PDB: 1M7Y, and PDB: 1YNU.
S-Arrestin is a protein found in mice that binds to rhodopsin to stop its activity, preventing further signaling. S-arrestin binds to G protein-coupled receptors (GPCRs), like rhodopsin, following receptor activation and phosphorylation by G protein-coupled receptor kinases (GRKs). Rhodopsin is found in rod cells of the retina, essential for vision. It detects light and initiates a signaling cascade called phototransduction. However, excessive activation can be harmful, so it must be carefully regulated. The phosphorylation of the receptor's intracellular loops and C-terminal tail creates a high-affinity binding site for S-arrestin. S-arrestin then sterically hinders further G protein coupling, effectively desensitizing the receptor and directing it towards alternative signaling pathways or internalization via clathrin-mediated endocytosis.
The classical, histopathological definition of amyloid is an extracellular, proteinaceous fibrillar deposit exhibiting β-sheet secondary structure and identified by apple-green birefringence when stained with congo red under polarized light. These deposits often recruit various sugars and other components such as serum amyloid P component, resulting in complex, and sometimes inhomogeneous structures. Recently this definition has come into question as some classic, amyloid species have been observed in distinctly intracellular locations. A more recent, biophysical definition is broader, including any polypeptide that polymerizes to form a cross-β structure, in vivo or in vitro, inside or outside cells. Microbiologists, biochemists, biophysicists, chemists and physicists have largely adopted this definition, leading to some conflict in the biological community over an issue of language.
Sources: en.wikipedia.org
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.
UHPLC uses columns with smaller particles and operates at higher pressures than conventional HPLC. These conditions can improve speed, resolution, and sensitivity. Both techniques use the same fundamental separation principles.
Validation shows that a method performs reliably for its intended purpose across a defined range. It assesses accuracy, precision, specificity, linearity, and robustness. Regulated testing often requires documented validation before routine use.
HPLC testing measures the presence and amount of one or more compounds in a liquid sample. It separates mixture components and records detector responses as peaks, which are compared with reference standards. Results are usually reported as concentrations or relative percentages.