Quality control raises a handful of sensible questions. This page answers them in order, starting with the fundamentals and moving to applications.
This page was last updated on 2026-07-20 and is reviewed periodically as new material appears.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
| Property | Value | Notes |
|---|---|---|
| Validation parameter | Accuracy | Closeness to a reference value. |
| Validation parameter | Precision | Repeatability or intermediate precision. |
| Validation parameter | Linearity | Proportional response across a range. |
| System suitability check | Resolution | Separation between adjacent peaks. |
| Quality control tool | Control chart | Tracks results over time for trends. |
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
The Oddo–Harkins rule holds that elements with even atomic numbers are more common than those with odd atomic numbers, with the exception of hydrogen and beryllium. This rule argues that elements with odd atomic numbers have one unpaired proton and are more likely to capture another, thus increasing their atomic number. In elements with even atomic numbers, protons are paired, with each member of the pair offsetting the spin of the other, enhancing stability. All the alkali metals have odd atomic numbers and they are not as common as the elements with even atomic numbers adjacent to them (the noble gases and the alkaline earth metals) in the Solar System. The heavier alkali metals are also less abundant than the lighter ones as the alkali metals from rubidium onward can only be synthesised in supernovae and not in stellar nucleosynthesis. Lithium is also much less abundant than sodium and potassium as it is poorly synthesised in both Big Bang nucleosynthesis and in stars: the Big Bang could only produce trace quantities of lithium, beryllium and boron due to the absence of a stable nucleus with 5 or 8 nucleons, and stellar nucleosynthesis could only pass this bottleneck by the triple-alpha process, fusing three helium nuclei to form carbon, and skipping over those three elements.
Automated synthesis or automatic synthesis is a set of techniques that use robotic equipment to perform chemical synthesis using a robotic system run using software control. Automating processes allows for higher efficiency and product quality although automation technology can be cost-prohibitive and there are concerns regarding overdependence and job displacement. Chemical processes were automated throughout the 19th and 20th centuries, with major developments happening in the previous thirty years, as technology advanced. Tasks that are performed may include: synthesis in variety of different conditions, sample preparation, purification, and extractions. Applications of automated synthesis are found on research and industrial scales in a wide variety of fields including polymers, personal care, and radiosynthesis.
Fatty change, or steatosis, is the accumulation of fatty acids in liver cells. This can be seen as fatty globules under the microscope. Alcoholism causes development of large fatty globules (macro-vesicular steatosis) throughout the liver and can begin to occur after a few days of heavy drinking. Alcohol is metabolized by alcohol dehydrogenase (ADH) into acetaldehyde, then further metabolized by aldehyde dehydrogenase (ALDH) into acetic acid, which is finally oxidized into carbon dioxide (CO2) and water (H2O). This process generates NADH, and increases the NADH/NAD+ ratio. A higher NADH concentration induces fatty acid synthesis while a decreased NAD level results in decreased fatty acid oxidation. Subsequently, the higher levels of fatty acids signal the liver cells to compound it to glycerol to form triglycerides. These triglycerides accumulate, resulting in fatty liver.
Antibody–drug conjugates or ADCs are a class of bioconjugates and immunoconjugates. ADCs are composed of an antibody linked to a cytotoxic (anticancer) "payload" or drug. Among treatment options for cancer, chemotherapy is most widely used. Its main limitation is low target specificity. Unlike chemotherapy, ADCs target tumor cells while sparing healthy cells. As of 2019, some 56 pharmaceutical companies were developing ADCs. ADCs combine the targeting properties of monoclonal antibodies with the cancer-killing capabilities of cytotoxic drugs, designed to discriminate between healthy and diseased tissue.
Three dimensional structure of none of the members of Angiopoietin like proteins (ANGPTLs) is available up until now. However, the structure of ANGPTL8 was predicted by homology modeling and is also reported in literature. It consists of alpha helices and its sequence show high similarity with the coiled-coil domains of ANGPTL3 and ANGPTL4. The ANGPTL8 regulatory pathway has been constructed recently by integrating the information of its known transcription factors which is available at WikiPathways data repository with the pathway id WP3915.
Sources: en.wikipedia.org
There are numerous theories as to the exact cause and mechanism in type 2 diabetes. Central obesity is known to predispose individuals for insulin resistance. Abdominal fat is especially active hormonally, secreting a group of hormones called adipokines that may possibly impair glucose tolerance. But adiponectin, an anti-inflammatory adipokine, which is found in lower concentration in obese and diabetic individuals has shown to be beneficial and protective in type 2 diabetes mellitus (T2DM). Insulin resistance is a major feature of diabetes mellitus type 2, and central obesity is correlated with both insulin resistance and T2DM itself. Increased adiposity (obesity) raises serum resistin levels, which in turn directly correlate to insulin resistance. Studies have also confirmed a direct correlation between resistin levels and T2DM. And it is waistline adipose tissue (central obesity) which seems to be the foremost type of fat deposits contributing to rising levels of serum resistin. Conversely, serum resistin levels have been found to decline with decreased adiposity following medical treatment.
While the initial consolidation of Air Force laboratories reduced overhead and budgetary pressure, another push towards a unified laboratory structure came in the form of the National Defense Authorization Act for Fiscal Year 1996, Section 277. This section instructed the Department of Defense to produce a five-year plan for consolidation and restructuring of all defense laboratories. The currently existing laboratory structure was created in October 1997 through the consolidation of Phillips Laboratory headquartered in Albuquerque, New Mexico, Wright Laboratory in Dayton, Ohio, Rome Laboratory (formerly Rome Air Development Center) in Rome, New York, and Armstrong Laboratory in San Antonio, Texas and the Air Force Office of Scientific Research (AFOSR). The single laboratory concept was developed and championed by Maj Gen Richard Paul, who was Director of Science & Technology for AFMC and Gen Henry Viccellio Jr, and then became the first Commander of AFRL.
MAAs are able to absorb UV light. A study published in 1976 demonstrated that an increase in MAA content was associated with an increase in photosynthetic respiration. Further studies done in marine cyanobacteria showed that the MAAs synthesized in response to UV-B correlated with an increase in photosynthetic pigments. Though not absolute proof, these findings do implicate MAAs as accessory pigments to photosynthesis. The eyes for the mantis shrimp contain four different kinds of mycosporine-like amino acids as filters, which combined with two different visual pigments assist the eye to detect six different bands of ultraviolet light. Three of the filter MAAs are identified with porphyra-334, mycosporine-gly, and gadusol.
Christopher A. Lipinski is a medicinal chemist who is working at Pfizer, Inc. He is known for his "rule of five", an algorithm that predicts drug compounds that are likely to have oral activity. By the number of citations, he is the most cited author of some pharmacology journals: Journal of Pharmacological and Toxicological Methods, Advanced Drug Delivery Reviews, Drug Discovery Today: Technologies. Lipinski received his PhD from the University of California, Berkeley in 1968 in physical organic chemistry. The Advanced Drug Delivery Reviews article reporting his "rule of five" is one of the most cited publications in the journal's history. In 2006, he received an honorary law degree from the University of Dundee and he has won various awards, including being the Society for Biomolecular Sciences' winner of the 2006 SBS Achievement Award for Innovation in HTS.
Sources: en.wikipedia.org
For decades, the public viewed the house as the "Birthplace of Insulin," and many individuals expressed their desire to have it turned into a shrine or monument to honour the Canadian hero. It was first internationally referred to with the title "Birthplace of Insulin," in 1923, by the Detroit Free Press. After 47 years, the house received official recognition in 1970, in the form of a plaque for the house, awarded by the London Public Library Board. In 1981, the London & District Branch of the Canadian Diabetes Association purchased the house, and began to use it as an office; they hoped to eventually restore the house, and turn it into a museum. Through various grants and fundraising efforts, by 1984, the museum was operational.
G-protein-coupled receptor oligomerisation is a widespread phenomenon. One of the best-studied examples is the metabotropic GABAB receptor. This so-called constitutive receptor is formed by heterodimerization of GABABR1 and GABABR2 subunits. Expression of the GABABR1 without the GABABR2 in heterologous systems leads to retention of the subunit in the endoplasmic reticulum. Expression of the GABABR2 subunit alone, meanwhile, leads to surface expression of the subunit, although with no functional activity (i.e., the receptor does not bind agonist and cannot initiate a response following exposure to agonist). Expression of the two subunits together leads to plasma membrane expression of functional receptor. It has been shown that GABABR2 binding to GABABR1 causes masking of a retention signal of functional receptors.
Volanesorsen was approved by the European Medicines Agency (EMA) for the treatment of familial chylomicronaemia syndrome in May 2019. In January 2013 mipomersen (marketed as Kynamro) was approved by the FDA for the treatment of homozygous familial hypercholesterolemia. Inotersen received FDA approval for the treatment of hereditary transthyretin-mediated amyloidosis in October 2018. The application for inotersen was granted orphan drug designation. It was developed by Ionis Pharmaceuticals and licensed to Akcea Therapeutics. Patisiran (sold under Onpattro) was developed by Alnylam Pharmaceuticals, and also approved for use in the US and EU in 2018 with orphan drug designation. Its mechanism-of-action is the active substance of small interfering RNA (siRNA), which allows it to interfere with and block the production of transthyretin. As such, it was the first FDA-approved siRNA therapeutic.
Sources: en.wikipedia.org
Method validation is the documented process of showing that an HPLC procedure produces reliable results for a defined purpose. It examines parameters such as accuracy, precision, specificity, linearity, and robustness. Regulators and quality systems often require validation before routine use.
System suitability is a set of checks run on the chromatographic system before sample analysis. It confirms that resolution, peak shape, retention time, and response meet predefined limits. Failure can invalidate the run and trigger corrective action.
Blank injections reveal peaks or baseline disturbances that come from solvents, reagents, or the instrument rather than the sample. They help distinguish contamination from actual analyte signals. Comparing blanks with sample runs supports accurate interpretation.
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.