Validation And Quality Control — Common Mistakes

By Editorial Desk · published 2025-09-08 · last reviewed 2025-10-26 · Blog

Quality control raises a handful of sensible questions. This page answers them in order, starting with the fundamentals and moving to applications.

Reviewed 2025-10-26. Anything still debated is marked as such rather than presented as settled.

Validation and Quality Control

System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.

Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.

Principles and Instrumentation

Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.

High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.

Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.

Hplc-testing at a glance

PropertyValueNotes
Validation parameterAccuracyCloseness to a reference value.
Validation parameterPrecisionRepeatability or intermediate precision.
Validation parameterLinearityProportional response across a range.
System suitability checkResolutionSeparation between adjacent peaks.
Quality control toolControl chartTracks results over time for trends.

Method Development and Validation

Validation establishes that a method is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, robustness, and stability of standards and samples. Acceptance criteria are defined in advance, and results are documented in a validation report. Regulatory guidance for pharmaceuticals, foods, and environmental testing differs, so the applicable framework must be identified. Ongoing verification uses control samples and trend charts after validation. Method transfer to another laboratory may require partial revalidation.

Routine quality control includes blanks, duplicates, spiked samples, and certified reference materials. Calibration curves are prepared with standards at several concentrations, and the detector response is checked for linearity. Carryover, column aging, mobile phase evaporation, and temperature drift can shift retention times or peak areas. Maintenance such as replacing seals, filters, and columns helps prevent failures. Records of injections, integration, and deviations support traceability. Audits may request raw data and instrument logs for each batch.

Related pages on this site

Background and Purpose of HPLC Testing

HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.

Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.

Background from the literature

The American Society of Plant Biologists (ASPB) is a non-profit professional society for research and education in plant science. It was founded in 1924 as the American Society of Plant Physiologists (ASPP); the name was changed in 2001. Membership in the society is open to any person from any country who deals with physiology, molecular biology, environmental biology, cell biology and plant biophysics or related issues. It has over 4,000 members worldwide. The society publishes the peer-reviewed journals Plant Physiology (1926–) and The Plant Cell (1989–) as well as ASPB News. The American Society of Plant Biologists also has partnered with the Society for Experimental Biology, and John Wiley & Sons to publish an online-only science journal Plant Direct. In 2000, it published the first edition of the textbook Biochemistry & Molecular Biology of Plants. The first President of the Society was Charles Albert Shull (1924–1925), with founder R. B. Harvey as Secretary-Treasurer. Other presidents of the Society include Harry Beevers (1961–1962), Aubrey Naylor (1960–1961), and Katayoon Dehesh (2021-2022). The first woman to be president of the society was Elisabeth Gantt (1988–1989).

At the regulatory site, the binding of a ligand may elicit amplified or inhibited protein function. The binding of a ligand to an allosteric site of a multimeric enzyme often induces positive cooperativity, that is the binding of one substrate induces a favorable conformation change and increases the enzyme's likelihood to bind to a second substrate. Regulatory site ligands can involve homotropic and heterotropic ligands, in which single or multiple types of molecule affects enzyme activity respectively. Enzymes that are highly regulated are often essential in metabolic pathways. For example, phosphofructokinase (PFK), which phosphorylates fructose in glycolysis, is largely regulated by ATP. Its regulation in glycolysis is imperative because it is the committing and rate limiting step of the pathway. PFK also controls the amount of glucose designated to form ATP through the catabolic pathway. Therefore, at sufficient levels of ATP, PFK is allosterically inhibited by ATP. This regulation efficiently conserves glucose reserves, which may be needed for other pathways. Citrate, an intermediate of the citric acid cycle, also works as an allosteric regulator of PFK.

Asparagine peptide lyase are one of the seven groups in which proteases, also termed proteolytic enzymes, peptidases, or proteinases, are classified according to their catalytic residue. The catalytic mechanism of the asparagine peptide lyases involves an asparagine residue acting as nucleophile to perform a nucleophilic elimination reaction, rather than hydrolysis, to catalyse the breaking of a peptide bond. The existence of this seventh catalytic type of proteases, in which the peptide bond cleavage occurs by self-processing instead of hydrolysis, was demonstrated with the discovery of the crystal structure of the self-cleaving precursor of the Tsh autotransporter from E. coli. These enzymes are synthesized as precursors or propeptides, which cleave themselves by an autoproteolytic reaction. The self-cleaving nature of asparagine peptide lyases contradicts the general definition of an enzyme given that the enzymatic activity destroys the enzyme. However, the self-processing is the action of a proteolytic enzyme, notwithstanding the enzyme is not recoverable from the reaction.

After a vascular injury occurs, platelets are activated by locally exposed collagen (glycoprotein (GP) VI receptor), locally generated thrombin (PAR1 and PAR4 receptors), platelet-derived thromboxane A2 (TxA2) (TP receptor) and ADP (P2Y1 and P2Y12 receptors) that is either released from damaged cells or secreted from platelet dense granules. The von Willebrand factor (VWF) serves as an essential accessory molecule. In general terms, platelet activation initiated by agonist takes to a signaling cascade that leads to an increase of the cytosolic calcium concentration. Consequently, the integrin αIIbβ3 is activated and the binding to fibrinogen allows the aggregation of platelets to each other. The increase of cytosolic calcium also leads to shape change and TxA2 synthesis, leading to signal amplification.

The first class of adenylyl cyclases occur in many bacteria including E. coli (as CyaA P00936 [unrelated to the Class II enzyme]). This was the first class of AC to be characterized. It was observed that E. coli deprived of glucose produce cAMP that serves as an internal signal to activate expression of genes for importing and metabolizing other sugars. cAMP exerts this effect by binding the transcription factor CRP, also known as CAP. Class I AC's are large cytosolic enzymes (~100 kDa) with a large regulatory domain (~50 kDa) that indirectly senses glucose levels. As of 2012, no crystal structure is available for class I AC. Some indirect structural information is available for this class. It is known that the N-terminal half is the catalytic portion, and that it requires two Mg2+ ions. S103, S113, D114, D116 and W118 are the five absolutely essential residues. The class I catalytic domain (Pfam PF12633) belongs to the same superfamily (Pfam CL0260) as the palm domain of DNA polymerase beta (Pfam PF18765). Aligning its sequence onto the structure onto a related archaeal CCA tRNA nucleotidyltransferase (PDB: 1R89​) allows for assignment of the residues to specific functions: γ-phosphate binding, structural stabilization, DxD motif for metal ion binding, and finally ribose binding.

Sources: en.wikipedia.org

Further detail

AM function can be compared to another peptide called pro-adrenomedullin N-terminal 20 peptide (PAMP), which both originate from a common precursor leading to angiogenesis, vasodilation, and anti-inflammatory processes. These two peptides are expressed in the gastrointestinal (GI) tract at a mass level, serving as GI hormones controlling processes like insulin secretion and gastric emptying. Past studies reveal that AM and PAMP also impact gut microbiome composition by fostering the development of beneficial bacteria (i.e., Bifidobacterium and Lactobacillus) and diminishing detrimental microbes.

The cellular response in signal transduction cascades involves alteration of the expression of effector genes or activation/inhibition of targeted proteins. Regulation of protein activity mainly involves phosphorylation/dephosphorylation events, leading to its activation or inhibition. It is the case for the vast majority of responses as a consequence of the binding of the primary messengers to membrane receptors. This response is quick, as it involves regulation of molecules that are already present in the cell. On the other hand, the induction or repression of the expression of genes requires the binding of transcriptional factors to the regulatory sequences of these genes. The transcriptional factors are activated by the primary messengers, in most cases, due to their function as nuclear receptors for these messengers. The secondary messengers like DAG or Ca2+ could also induce or repress gene expression, via transcriptional factors. This response is slower than the first because it involves more steps, like transcription of genes and then the effect of newly formed proteins in a specific target. The target could be a protein or another gene.

Adenylyl cyclase is regulated by G proteins, which can be found in the monomeric form or the heterotrimeric form, consisting of three subunits. Adenylyl cyclase activity is controlled by heterotrimeric G proteins. The inactive or inhibitory form exists when the complex consists of alpha, beta, and gamma subunits, with GDP bound to the alpha subunit. In order to become active, a ligand must bind to the receptor and cause a conformational change. This conformational change causes the alpha subunit to dissociate from the complex and become bound to GTP. This G-alpha-GTP complex then binds to adenylyl cyclase and causes activation and the release of cAMP. Since a good signal requires the help of enzymes, which turn on and off signals quickly, there must also be a mechanism in which adenylyl cyclase deactivates and inhibits cAMP. The deactivation of the active G-alpha-GTP complex is accomplished rapidly by GTP hydrolysis due to the reaction being catalyzed by the intrinsic enzymatic activity of GTPase located in the alpha subunit. It is also regulated by forskolin, as well as other isoform-specific effectors:

Apryll Marie Stalcup is an American chemist who is Professor and was the Director of the Irish Separation Science Cluster at Dublin City University. She was awarded the 2021 Chromatography Forum of the Delaware Valley Stephen Dal Nogare Award, the 2015 American Microchemical Society Benedetti Pichler Award and named in the 2016 Power List of the Top 50 Women Analytical Scientists worldwide. Her research considers surface-confined ionic liquids and chiral separations.

Sources: en.wikipedia.org

Frequently asked questions

What is method validation in HPLC?

Method validation is the documented process of showing that an HPLC procedure produces reliable results for a defined purpose. It examines parameters such as accuracy, precision, specificity, linearity, and robustness. Regulators and quality systems often require validation before routine use.

What is system suitability?

System suitability is a set of checks run on the chromatographic system before sample analysis. It confirms that resolution, peak shape, retention time, and response meet predefined limits. Failure can invalidate the run and trigger corrective action.

Why are blank injections used?

Blank injections reveal peaks or baseline disturbances that come from solvents, reagents, or the instrument rather than the sample. They help distinguish contamination from actual analyte signals. Comparing blanks with sample runs supports accurate interpretation.

What does HPLC measure?

HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.